Allowable heat load on the edge of the ITER first wall panel beryllium flat tiles

R. Mitteau,R. Eaton,A. Gervash, V. Kuznetcov,V. Davydov, R. Rulev

NUCLEAR MATERIALS AND ENERGY(2017)

引用 7|浏览18
暂无评分
摘要
Plasma facing components are usually qualified to a given heat load density applied at the top face of the armour tiles with normal incidence angle. When employed in tokamak fusion machines, heat loading on the tile sides is possible due to optimised shaping, that doesn't provide edge shadowing for all design situations. An edge heat load may occur both at the tile and component scales. The edge load needs to be controlled and quantified. The adequate control of edge heat loads is especially critical for water cooled components that uses armour tiles which are bonded to the heat sink, for ensuring the long-term integrity of the tile bonding. An edge heat load allowance criterion of 10% of the top heat load is proposed. The 10% criterion is supported by experimental heat flux tests. (C) 2017 ITER organisation. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license. (http://creativecommons.org/licenses/by-nc-nd/4.0/)