Field Evaluation Of Dried Blood Spots For Hiv-1 Viral Load Monitoring In Adults And Children Receiving Antiretroviral Treatment In Kenya: Implications For Scale-Up In Resource-Limited Settings

Mary E. Schmitz, Simon Agolory,Muthoni Junghae,Laura N. Broyles, Muthusi Kimeu, Joseph Ombayo, Mamo Umuro,Irene Mukui, Kennedy Alwenya, Moses Baraza,Kenneth Ndiege,Samuel Mwalili, Emilia Rivadeneira, Lucy Ng'Ang'A,Chunfu Yang,Clement Zeh

JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES(2017)

引用 27|浏览16
暂无评分
摘要
Background: The World Health Organization recommends viral load (VL) as the preferred method for diagnosing antiretroviral therapy failure; however, operational challenges have hampered the implementation of VL monitoring in most resource-limited settings. This study evaluated the accuracy of dried blood spot (DBS) VL testing under field conditions as a practical alternative to plasma in determining virologic failure (VF).Methods: From May to December 2013, paired plasma and DBS specimens were collected from 416 adults and 377 children on antiretroviral therapy for >= 6 months at 12 clinics in Kenya. DBSs were prepared from venous blood (V-DBS) using disposable transfer pipettes and from finger-prick capillary blood using microcapillary tubes (M-DBS) and directly spotting (D-DBS). All samples were tested on the Abbott m2000 platform; V-DBS was also tested on the Roche COBAS Ampliprep/COBAS TaqMan (CAP/CTM) version 2.0 platform. VF results were compared at 3 DBS thresholds (>= 1000, >= 3000, and >= 5000 copies/mL) and a constant plasma threshold of >= 1000 copies/mL.Results: On the Abbott platform, at > 1000-copies/mL threshold, sensitivities, specificities, and kappa values for VF determination were >= 88.1%, >= 93.1%, and >= 0.82%, respectively, for all DBS methods, and it had the lowest percentage of downward misclassification compared with higher thresholds. V-DBS performance on CAP/CTM had significantly poorer specificity at all thresholds (1000%-33.0%, 3000%-60.9%, and 5000%-77.0%). No significant differences were found between adults and children.Conclusions: VL results from V-DBS, M-DBS, and D-DBS were comparable with those from plasma for determining VF using the Abbott platform but not with CAP/CTM. A 1000-copies/mL threshold was optimal and should be considered for VF determination using DBS in adults and children.
更多
查看译文
关键词
HIV,viral load,resource-limited settings,HIV RNA,dried blood spots,Kenya
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要