Measurement of thermal transmittance of opaque facade wall relationship with meteorological conditions

Tehnika(2015)

引用 1|浏览0
暂无评分
摘要
This paper presents the results of measurements of thermal transmittance or as otherwise called U-value [W/m2⋅K] of opaque facade wall of preschool institution built in 1977. The building has an incomplete technical documentation according to which considered wall was built of brick and masonry mortar. Thermal characteristics of the incorporated materials have not been specified. Considering that in the period of building construction JUS standards was used, a possible range of calculated U-vales was obtained (1,241-1,404 W/m2·K). Measurements were performed in accordance with ISO 9869 during three time periods with the resulting U-values (1,269±0,276 W/m2·K; 1,025±0,175 W/m2·K; 1,200±0,212 W/m2·K) that do not differ from each other within experimental uncertainty. Furthermore, the correlation of the measured U-values and meteorological conditions that prevailed during the measurements was analyzed. In the second measurement period, the average values of the total cloud cover and low cloud cover were less, and the average duration of sunshine was longer than in the other two measurement periods.
更多
查看译文
关键词
thermal transmittance,in-situ measurement,meteorological conditions