Gas bremsstrahlung shielding calculation for first optic enclosure of ILSF medical beamline

JOURNAL OF INSTRUMENTATION(2016)

引用 2|浏览3
暂无评分
摘要
Gas bremsstrahlung is generated in high energy electron storage ring accompanies the synchrotron radiation into the beamlines and strike the various components of the beamline. In this paper, radiation shielding calculation for secondary gas bremsstrahlung is performed for the first optics enclosure (FOE) of medical beamline of the Iranian Light Source Facility (ILSF). Dose equivalent rate (DER) calculation is accomplished using FLUKA Monte Carlo code. A comprehensive study of DER distribution at the back wall, sides and roof is given.
更多
查看译文
关键词
Radiation calculations,Simulation methods and programs,Dosimetry concepts and apparatus,Instrumentation for synchrotron radiation accelerators