Utilizing the N beam position monitor method for turn-by-turn optics measurements

PHYSICAL REVIEW ACCELERATORS AND BEAMS(2016)

Cited 5|Views5
No score
Abstract
The N beam position monitor method (N-BPM) which was recently developed for the LHC has significantly improved the precision of optics measurements that are based on BPM turn-by-turn data. The main improvement is due to the consideration of correlations for statistical and systematic error sources, as well as increasing the amount of BPM combinations which are used to derive the beta-function at one location. We present how this technique can be applied at light sources like ALBA, and compare the results with other methods.
More
Translated text
Key words
thenbeam position monitor method,optics,turn-by-turn
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined