Quantitative computed tomography measurements to evaluate airway disease in chronic obstructive pulmonary disease: Relationship to physiological measurements, clinical index and visual assessment of airway disease

European Journal of Radiology(2016)

Cited 73|Views13
No score
Abstract
Abstract Purpose To correlate currently available quantitative CT measurements for airway disease with physiological indices and the body-mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in patients with chronic obstructive pulmonary disease (COPD). Materials and methods This study was approved by our institutional review board (IRB number 2778). Written informed consent was obtained from all subjects. The subjects included 188 current and former cigarette smokers from the COPDGene cohort who underwent inspiratory and expiratory CT and also had physiological measurements for the evaluation of airflow limitation, including FEF25-75%, airway resistance (Raw), and specific airway conductance (sGaw). The BODE index was used as the index of clinical symptoms. Quantitative CT measures included % low attenuation areas [% voxels ≤ 950 Hounsfield unit (HU) on inspiratory CT, %LAA −950ins ], percent gas trapping (% voxels ≤ −856 HU on expiratory CT, %LAA −856exp ), relative inspiratory to expiratory volume change of voxels with attenuation values from −856 to −950 HU [Relative Volume Change (RVC) −856 to −950 ], expiratory to inspiratory ratio of mean lung density (E/I-ratio MLD ), Pi10, and airway wall thickness (WT), luminal diameter (LD) and airway wall area percent (WA%) in the segmental, subsegmental and subsubsegmental bronchi on inspiratory CT. Correlation coefficients were calculated between the QCT measurements and physiological measurements in all subjects and in the subjects with mild emphysema (%LAA −950ins Results Quantitative CT measurements had significant correlations with physiological indices. Among them, E/I-ratio MLD had the strongest correlations with FEF25-75% (r = −0.648, −856 to −950 was an independent predictor of the BODE index showing the highest R 2 (0.468) as an independent variable among the QCT measurements. Conclusion Quantitative CT measurements of gas trapping such as E/I-ratio MLD , correlate better with physiological indices for airway disease than those of airway such as WA% or LD. In mild emphysema, however, quantitative CT measurements of airway correlate better with the physiological indices. RVC −856 to −950 is a predictor of the BODE index.
More
Translated text
Key words
Chronic obstructive lung disease (COPD),CT,Airway disease,Air trapping,Quantitative CT
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined