Implementation Of Non-Intrusive Jet Exhaust Species Distribution Measurements Within A Test Facility

ieee aerospace conference(2016)

引用 8|浏览18
暂无评分
摘要
We report on the installation and commissioning of two systems for the measurement of cross-sectional distributions of pollutant species in jet exhaust, within the engine ground test facility at INTA, Madrid. These systems use optical tomography techniques to estimate the cross-sectional distributions of CO2 and soot immediately behind the engine. The systems are designed to accommodate the largest civil aviation engines currently in service, without obstruction of the exhaust or bypass flows and with negligible effect upon the entrained flow behavior. We describe the physical construction and installation status of each system. In the case of the CO2 system, we examine the challenges of achieving the structural rigidity necessary for adequate suppression of pointing error within 126 laser-based transmittance measurements, each utilizing a 7 m overall path length. We describe methods developed for efficient implementation of co-planarity and 4-degree- of-freedom alignment of individual paths within this beam array. We also present laboratory performance data for three alternative optical designs that differ in their approach to the management of pointing error and turbulence-induced beam wander and spread. The FLITES soot monitoring capability is based on laser induced incandescence (LII) and uses a short-pulse fiber laser and two CCD cameras, in an autoprojection arrangement. We describe the measurement geometry currently being implemented in the test cell and discuss optical design issues, including once again the effect of the plume itself.
更多
查看译文
关键词
nonintrusive jet exhaust species distribution measurements,cross-sectional distribution measurement,pollutant species,engine ground test facility,INTA,Madrid,optical tomography techniques,cross-sectional CO2 distribution,soot distributions,civil aviation engines,bypass flows,exhaust flows,entrained flow behavior,physical construction,installation status,CO2 system,structural rigidity,pointing error suppression,laser-based transmittance measurements,path length,4- degree-of-freedom alignment,laboratory performance data,turbulence-induced beam,FLITES soot monitoring capability,laser induced incandescence,LII,short-pulse fiber laser,CCD cameras,autoprojection arrangement,measurement geometry,test cell,optical design,plume effect,distance 7 m,CO2
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要