Production of high purity water using membrane-free electrodeionization with improved resin layer structure

Separation and Purification Technology(2016)

引用 21|浏览7
暂无评分
摘要
•Ions backward migration was prevented by adjusting the ratio of mixed resin.•MFEDI could be operated without electrode polarity reversal.•Critical current density was 63A/m2 for this MFEDI system.•Good purification and effective regeneration were achieved.•Energy consumption and water recovery were 0.24kWh/m3 water and 96.1%.
更多
查看译文
关键词
Membrane-free electrodeionization,Desalination,Ion backward migration prevention,Resins electrical regeneration,Water dissociation