谷歌浏览器插件
订阅小程序
在清言上使用

SUV measurement of normal vertebrae using SPECT/CT with Tc-99m methylene diphosphonate.

AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING(2016)

引用 74|浏览8
暂无评分
摘要
The purpose of this study is to perform quantitative measurement based on the standardized uptake value (SUV) of the uptake of Tc-99m methylene diphosphonate (MDP) in the normal vertebrae using a single photon emission tomography (SPECT)/computed tomography (CT) scanner. A retrospective study of patients with cancer or joint disorders was performed. We acquired data for a group of 29 patients (8 women and 21 men; mean age, 68.2 +/- 6.7 years; age range, 44-87 years) undergoing bone SPECT/CT scans with Tc-99m MDP between September and October 2015. Various SUVs were calculated based on body-weight, lean-body-weight (lbw), Japanese lean-bodyweight (jlbw) and Japanese bone-mineral-content (jbmc). SUVs of normal vertebrae showed a wide range of values. Among these, the maximum body-weight based SUV showed the lowest coefficient of variation. The SUVs also showed relatively small intra-subject variability. In addition, all SUVs showed moderate and significant correlation with height. Moreover, lbw-, jlbw-, and jbmc-based SUVs of men were significantly higher than those of women. In conclusions, SUVs of normal vertebrae showed a relatively large inter-individual variability and small intra-individual variability. As a quantitative imaging biomarker, SUVs might require standardization with adequate reference data for the same subject to minimize variability.
更多
查看译文
关键词
SUV,bone,SPECT,SPECT/CT,QIBA
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要