Evaluation of Three Point-of-Care Tests for Detection of Toxoplasma Immunoglobulin IgG and IgM in the United States: Proof of Concept and Challenges.
OPEN FORUM INFECTIOUS DISEASES(2018)
摘要
Background. The cost of conventional serological testing for toxoplasmosis discourages universal adoption of prenatal monthly screening programs to prevent congenital toxoplasmosis. Point-of-care (POC) technology may constitute a cost-effective approach. Methods. We evaluated the diagnostic accuracy of 3 Toxoplasma POC tests against gold-standard testing performed at Palo Alto Medical Foundation Toxoplasma Serology Laboratory (PAMF-TSL). The POC tests included the following: Toxo IgG/IgM Rapid Test (Biopanda) and the OnSite Toxo IgG/IgM Combo-Rapid-test that detect IgG and IgM separately, and the Toxoplasma ICT-IgG-IgM-bk (LDBIO) that detects either or both immunoglobulin IgG/IgM in combination. Samples were selected from PAMF-TSL biobank (n = 210) and Centers for Disease Control and Prevention Toxoplasma 1998 Human Serum Panel (n = 100). Based on PAMF-TSL testing, Toxoplasma-infection status was classified in 4 categories: acute infections (n = 85), chronic infections (n = 85), false-positive Toxoplasma IgM (n = 60), and seronegative (n = 80). The POC testing was performed in duplicate following manufacturer's instructions by investigators blinded to PAMF-TSL results. Sensitivity and specificity were calculated. Results. A total of 1860 POC tests were performed. For detection of Toxoplasma IgG, sensitivity was 100% (170 of 170; 95% confidence interval [CI], 97.8%-100%) for all 3 POC kits; specificity was also comparable at 96.3% (77 of 80; 95% CI, 89.5%98.9%), 97.5% (78 of 80; 95% CI, 91.3%-99.6%), and 98.8% (79 of 80; 95% CI, 93.2%-99.9%). However, sensitivity for detection of Toxoplasma IgM varied significantly across POC tests: Biopanda, 62.2% (51 of 82; 95% CI, 51.4%-71.9%); OnSite, 28% (23 of 82; 95% CI, 19.5%-38.6%); and LDBIO combined IgG/IgM, 100% (82 of 82; 95% CI, 95.5%-100%). Diagnostic accuracy was significantly higher for the LDBIO POC kit. The POC kits did not exhibit cross-reactivity for false-positive Toxoplasma-IgM sera. Conclusions. The 3 evaluated POC kits revealed optimal sensitivity for Toxoplasma-IgG antibodies. The LDBIO-POC test exhibited 100% sensitivity for the combined detection of IgG/IgM in acute and chronic Toxoplasma infection. Biopanda and Onsite POC tests exhibited poor sensitivity for Toxoplasma-IgM detection.
更多查看译文
关键词
immunoglobulin G,immunoglobulin M,Toxoplasma gondii,toxoplasmosis,point-of-care testing
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要