Improved Dose Estimates for Fluoroscopically Guided Lumbar Epidural Injections.

PAIN MEDICINE(2019)

引用 0|浏览19
暂无评分
摘要
Objective. The goal of the study was to determine the potential impact of system inaccuracies and table attenuation on fluoroscope-reported dose values. Design. An Institutional Review Board-approved study was conducted to collect detailed acquisition and patient exposure data for fluoroscopy-guided lumbar epidural injections. Background. System-reported dosimetry values, especially the air Kinetic Energy Released per unit MAss and dose-area product metrics, are routinely used for estimating the radiation burden to patients undergoing fluoroscopy-guided procedures. However, these metrics do not account for other factors, such as acquisition geometry, where the table may attenuate a substantial fraction of the x-ray intensity, and system dosimetry inaccuracies, which are only required to be accurate within +/- 35%. Methods. Acquisition data from 46 patients undergoing fluoroscopy-guided lumbar epidural injections were collected to better estimate the true incident dose-area product. Gantry angles, x-ray technique factors, and field sizes were collected to characterize each procedure. Additionally, the fluoroscope dosimetry accuracy and table attenuation properties were evaluated as a function of kVp to generate the correction factors necessary for accurate dosimetry estimates. Results. The system-reported values overestimated the total patient entrance dose-area product by an average of 34% (13-44%). Errors may be substantially higher for systems with less accurate fluoroscopes or more anterior-posterior projections. Correcting system-reported dosimetry values for systematic inaccuracies and variability can substantially improve fluoroscopic dose values. Conclusions. Including corrections for system output inaccuracies and acquisition factors such as table attenuation is necessary for any reliable assessment of radiation burden to patients associated with fluoroscopy-guided procedures.
更多
查看译文
关键词
Fluoroscopy,Radiation,Dose,DAP,Epidural,Low Back Pain
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要