Objective: The aim of this study was to investigate in the fetus the relationship between unexpected high middle cerebral artery peak systolic velocity (middle cerebral artery (MCA) peak systolic velocity (PSV)) values and hemoglobin (Hgb) levels in normal pregnancies without conditions leading to fetal anemia. Material and methods: This was a prospective study of 922 singleton low-risk pregnant women attending the maternity of La Fe Hospital between 35 and 41 weeks. Multiple pregnancies and pregnancies with growth restriction, smallness, macrosomia or conditions leading to fetal anemia were excluded. During each examination, a biometry and a Doppler examination of the umbilical artery pulsatility index (umbilical artery (UA) pulsatility index (PI)), MCA PI and MCA PSV were performed. MCA PSV was converted into multiples of median (MoM), and birth weight (BW) into centiles adjusting for gender. All pregnancies delivered in a 2-week interval since examination. In order to explain Hgb levels at birth, a correlation between MCA PSV MoM and Hgb was performed and Hgb levels of fetuses with normal MCA PSV and abnormal MCA PSV were compared, using 1.3 MoM as cut-off for mild anemia. Finally, a multivariate linear regression analysis was performed including MCA PSV MoM and several Doppler and clinical parameters. Results: The univariate analysis showed no correlation between the MCA PSV MoM and the umbilical artery Hgb (r(2) = 0.026, p = .1237) while a weak correlation was found with the umbilical vein Hgb (r(2) = 0.0053, p = .027). Also, fetuses with values of MCA PSV MoM 1.3 MoM (p = .99 and p = .61, respectively). Finally, both prediction models explaining arterial and venous Hgb presented very weak predictive accuracies (R Squared: 0.0965 and R Squared: 0.106) indicating a low possibility to diagnose fetal anemia in otherwise normal fetuses based on clinical and sonographic data. Conclusion: In normal pregnancies that are not suffering from conditions leading to fetal anemia, unexpected high MCA PSV values do not necessarily reflect the presence of this condition. Active management in this circumstance might result in unjustified higher rates of labor induction and operative delivery.
更多
查看译文
关键词
Fetal anemia,fetal doppler,fetal hemodynamics,middle cerebral artery,peak systolic velocity
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要