Suitability of melanoma FFPE samples for NGS libraries: time and quality thresholds for downstream molecular tests.

BIOTECHNIQUES(2018)

引用 14|浏览21
暂无评分
摘要
The use of NGS in clinical practice for precision diagnosis requires a quality starting material. Despite the broadly established use of formalin-fixed paraffin-embedded (FFPE) samples in molecular testing, these usually have low-quality DNA. We established a method to determine the suitability of melanoma FFPE samples for an amplicon-based NGS custom panel analysis. DNA was extracted from unstained melanoma samples and wide local excision samples. Amplicon-based libraries were constructed and tested using time and quality parameters as variables. Time elapsed from sample retrieval >7 years, a quality control value >5.63 and a DNA integrity value <2.05 indicated samples were not suitable. A decision tree is provided with rate of samples suitable for analysis according to the combination of these parameters.
更多
查看译文
关键词
DIN,FFPE,library,melanoma,NGS,QC,quality,threshold,time