Low reliability of anti-KIR4.1 83-120 peptide auto-antibodies in multiple sclerosis patients.

MULTIPLE SCLEROSIS JOURNAL(2018)

引用 6|浏览47
暂无评分
摘要
Background: Multiple sclerosis (MS) is an autoimmune disease for which auto-antibodies fully validated as diagnostic and prognostic biomarkers are widely desired. Recently, an immunoreactivity against the inward rectifying potassium channel 4.1 (KIR4.1) has been reported in a large proportion of a group of MS patients, with amino acids 83-120 being the major epitope. Moreover, a strong correlation between anti-KIR4.1(83-120) and anti-full-length-protein auto-antibodies titer was reported. However, this finding received limited confirmation. Objective: Validation of the diagnostic potential of anti-KIR4.1(83-120) antibodies in 78 MS patients, 64 healthy blood donors, and 42 individuals with other neurological diseases. Methods: Analysis of anti-KIR4.1(83-120) antibodies by enzyme-linked immunosorbent assay (ELISA) using a mouse antiserum we produced as a new ELISA reliability control. Additionally, evaluation of reactivity against 293-T cells transiently transfected with full-length KIR4.1 by flow cytometry. Results: We found antibodies to KIR4.1(83-120) only in 13 out of 78 (16.6%) MS patients; among these, only 2 were positive for anti-full-length KIR4.1 antibodies. Conclusion: Employing a new reliability control and a new cytofluorometric assay, we cannot support anti-KIR4.1(83-120) auto-antibodies as a reliable biomarker in MS.
更多
查看译文
关键词
KIR4,1,multiple sclerosis,auto-antibodies,biomarker,enzyme-linked immunosorbent assay,flow cytometry