The Role of Doppler Ultrassonography in Significant and Borderline Stenosis Definition.

BLOOD PURIFICATION(2018)

Cited 3|Views12
No score
Abstract
Background: The definition of significant stenosis (SS) remains controversial. Methods: We retrospectively reviewed 1,040 consultations. SS was defined in the presence of clinical and echo-Doppler (DDU) criteria: Qa <500 mL/min or Qa decrease > 25%; RI >0.7 in the feeding artery or absolute minimal luminal stenosis diameter <2.0 mm. Stenosis without any additional criteria were considered borderline stenosis (BS). Results: Two hundred twenty-one arteriovenous fistulas (AVFs) were included: 58.8% had SS, 18.6% had BS, and 22.6% had no dysfunctional access (ND). SS had a significantly higher thrombotic events than BS and ND (13.1 vs. 4.4%, p = 0.018). The annual thrombosis rate was 0.007, 0.037, and 0.004 in the ND, SS, and BS, respectively. AVF cumulative survival at 5 years was significantly lower in SS (89.5%) compared to BS (100%) and ND (97.4%; p = 0.03). BS had an HR for AVF failure of 1.1, p = 0.955, while the SS presented an HR of 5.9, p = 0.09. Conclusion: AVF clinical monitoring with additional DDU criteria appear to be appropriate for therapeutic referral. (C) 2018 S. Karger AG, Basel
More
Translated text
Key words
Significant stenosis,Borderline stenosis,Arteriovenous fistula,Thrombosis
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined