Comparing Different Recording Lengths of Dynamic Cerebral Autoregulation: 5 versus 10 Minutes.

BIOMED RESEARCH INTERNATIONAL(2018)

引用 12|浏览5
暂无评分
摘要
We compared the dynamic cerebral autoregulation (dCA) indices between 5-and 10-minute data lengths by analyzing 37 patients with ischemic stroke and 51 controls in this study. Correlation coefficient (Mx) and transfer function analysis were applied for dCA analysis. Mx and phase shift in all frequency bands were not significantly different between 5-and 10-minute recordings [mean difference: Mx = 0.02; phase shift of very low frequency (0.02-0.07Hz) = 0.3 degrees, low frequency (0.07-0.20Hz) = 0.6 degrees, and high frequency (0.20-0.50Hz) = 0.1 degrees]. However, the gains in all frequency bands of a 5-minute recording were slightly but significantly higher than those of a 10-minute recording (mean difference of gain: very low frequency = 0.05 cm/s/mmHg, low frequency = 0.11 cm/s/mmHg, and high frequency = 0.14 cm/s/mmHg). The intraclass correlation coefficients between all dCA indices of 5and 10-minute recordings were favorable, especially in Mx (0.93), phase shift in very low frequency (0.87), and gain in very low frequency (0.94). The areas under the receiver operating characteristic curve for stroke diagnosis between 5-and 10-minute recordings were not different. We concluded that dCA assessed by using a 5-minute recording is not significantly different from that using a 10-minute recording in the clinical application.