Comparison of interfragmentary compression in conventional and locked plating of proximal unicondylar tibia fractures : A biomechanical cadaver study.

S Rahm,L Ebneter, B Schultz,C Spross, F Kulling,J B Erhardt

Acta orthopaedica Belgica(2016)

Cited 24|Views0
No score
Abstract
The extent of interfragmentary compression in intra-articular fractures treated with various fixation methods have not yet been reported. Lateral split fractures were created in six pairs of cadaver tibiae treated -using buttress plating with lag screws (group C) or locked buttress plating after clamp compression (group L). Interfragmentary compression and fracture displacement were continuously measured using pressure sensors and a stereoscopic 3-D image correlation system. Significantly larger interfragmentary compression was found initially after clamping the fragment (p < 0.05) in group C (median ± SD ; 45.1 ± 5.0 N/mm2) compared with group L (33.6 ± 3.4 N/mm2), and a statistical trend towards larger compression was also found after cyclic loading (p = 0.05) in group C (45.3 ± 8.6 N/mm2) compared with group L (28.7 ± 5.8 N/mm2). These data indicate that conventional plating with lag screws achieves higher interfragmentary compression in this model compared with external clamp compression and locked plating.
More
Translated text
Key words
interfragmentary compression,tibia plateau fracture,conventional plating,locked plating