Evaluation Of Two Novel Integrated Stand-Alone Spacer Designs Compared With Anterior And Anterior-Posterior Single-Level Lumbar Fusion Techniques: An In Vitro Biomechanical Investigation

ASIAN SPINE JOURNAL(2017)

引用 3|浏览6
暂无评分
摘要
Study Design: In vitro biomechanical investigation.Purpose: To compare the biomechanics of integrated three-screw and four-screw anterior interbody spacer devices and traditional techniques for treatment of degenerative disc disease.Overview of Literature: Biomechanical literature describes investigations of operative techniques and integrated devices with four dual-stacked, diverging interbody screws; four alternating, converging screws through a polyether-ether-ketone (PEEK) spacer; and four converging screws threaded within the PEEK spacer. Conflicting reports on the stability of stand-alone devices and the influence of device design on biomechanics warrant investigation.Methods: Fourteen cadaveric lumbar spines were divided randomly into two equal groups (n=7). Each spine was tested intact, after discectomy (injured), and with PEEK interbody spacer alone (S), anterior lumbar plate and spacer (AP+S), bilateral pedicle screws and spacer (BPS+S), circumferential fixation with spacer and anterior lumbar plate supplemented with BPS, and three-screw (SA3s) or four-screw (SA4s) integrated spacers. Constructs were tested in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Researchers performed one-way analysis of variance and independent t-testing (p=0.05).Results: Instrumented constructs showed significantly decreased motion compared with intact except the spacer-alone construct in FE and AR (p=0.05). SA3s showed significantly decreased range of motion (ROM) compared with AP+ S in LB (p=0.05) and comparable ROM in FE and AR. The three-screw design increased stability in FE and LB with no significant differences between integrated spacers or between integrated spacers and BPS+S in all loading modes.Conclusions: Integrated spacers provided fixation statistically equivalent to traditional techniques. Comparison of three-screw and four-screw integrated anterior lumbar interbody fusion spacers revealed no significant differences, but the longer, larger-diameter interbody spacer with three-screw design increased stabilization in FE and LB; the diverging four-screw design showed marginal improvement during AR.
更多
查看译文
关键词
Intervertebral disc degeneration, Lumbar region, Range of motion, Equipment design
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要