Application of Sub- and Supercritical Freons in Xenogenic Bone Matrix Processing

D. Yu. Zalepugin, N. A. Tilkunova,I. V. Chernyshova, M. I. Vlasov

Russian Journal of Physical Chemistry B(2018)

引用 3|浏览8
暂无评分
摘要
Sub- and supercritical freons can be successfully used in the bone matrix cleaning process. In the case of freon R22 the duration of bone matrix cleaning significantly decreases as compared to the same procedure with supercritical carbon dioxide. Freons R23, R134 and R407c which do not contain chlorine atoms are almost ineffective in this process.
更多
查看译文
关键词
supercritical extraction,freons,carbon dioxide,xenogenic matrix