Short Acquisition Time PET Quantification Using MRI-Based Pharmacokinetic Parameter Synthesis.

MICCAI(2017)

引用 24|浏览39
暂无评分
摘要
Positron Emission Tomography (PET) with pharmacokinetic (PK) modelling is a quantitative molecular imaging technique, however the long data acquisition time is prohibitive in clinical practice. An approach has been proposed to incorporate blood flow information from Arterial Spin Labelling (ASL) Magnetic Resonance Imaging (MRI) into PET PK modelling to reduce the acquisition time. This requires the conversion of cerebral blood flow (CBF) maps, measured by ASL, into the relative tracer delivery parameter ((R_1)) used in the PET PK model. This was performed regionally using linear regression between population (R_1) and ASL values. In this paper we propose a novel technique to synthesise (R_1) maps from ASL data using a database with both (R_1) and CBF maps. The local similarity between the candidate ASL image and those in the database is used to weight the propagation of (R_1) values to obtain the optimal patient specific (R_1) map. Structural MRI data is also included to provide information within common regions of artefact in ASL data. This methodology is compared to the linear regression technique using leave one out analysis on 32 subjects. The proposed method significantly improves regional (R_1) estimation ((pu003c0.001)), reducing the error in the pharmacokinetic modelling. Furthermore, it allows this technique to be extended to a voxel level, increasing the clinical utility of the images.
更多