Hypercalcemia and elevated concentration of vitamin D: A case report too easy to be true.

Clinica chimica acta; international journal of clinical chemistry(2016)

引用 6|浏览19
暂无评分
摘要
BACKGROUND:Endogenous (heterophile, human anti-animal …) antibodies are a known cause of interference in immunoassays. CASE REPORT:A patient with hypercalcemia and low PTH levels was investigated. The serum 25OH vitamin D (25OHD) concentration was above the analytical range of the automated analyser (>150ng/mL) but serum dilutions were not linear. A myeloma-related monoclonal peak of immunoglobulin G (30g/L) was found. RESULTS:Alternative 25OHD assays (RIA, automated analysers, mass spectrometry) all found concentrations <25ng/mL. NabTM columns (Thermo Scientific) eliminated the endogenous immunoglobulin from the serum thus allowing the initial analyser to provide correct results. DISCUSSION AND CONCLUSION:The potentially misleading point was that the apparent very high 25OHD levels were concomitant with hypercalcemia and low PTH levels thus mimicking vitamin D intoxication. Identifying assay interferences requires clinical awareness but, when suspected, one should be aware that technical tools or alternate assays are available to correct some interferences, including monoclonal immunoglobulins.