Determination of "new psychoactive substances" in postmortem matrices using microwave derivatization and gas chromatography-mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences(2016)

Cited 22|Views2
No score
Abstract
Despite worldwide efforts aiming to ban the marketing and subsequent abuse of psychoactive substances such as synthetic cathinones and phenethylamines, there has been an alarming growth of both in recent years. Different compounds similar to those already existing are continuously appearing in the market in order to circumvent the legislation. An analytical methodology has been validated for qualitative and quantitative determinations of D-cathine (D-norpseudoehedrine), ephedrine, methcathinone, 1-(4-methoxyphenyl)-propan-2-amine (PMA), mephedrone, methedrone, 2,5-dimethoxy-4-methylamphetamine (DOM), 4-bromo-2,5-dimethoxyamphetamine (DOB), 2,5-dimethoxyphenethylamine (2C-H), 4-bromo-2,5-dimethoxyphenethylamine (2C-B), 4-iodo-2,5-dimethoxyphenethylamine (2C-I), 2-[2,5-dimethoxy-4-(ethylthio)phenyl]ethanamine (2C-T-2), 2,5-dimethoxy-4-isopropylthiophenethylamine (2C-T-4) and 2-[2,5-dimethoxy-4-(propylthio)phenyl]ethanamine (2C-T-7), in low volumes of vitreous humor (100 μL), pericardial fluid (250 μL) and whole blood (250 μL), using deutered amphetamine, ephedrine and mephedrone as internal standards. The validation parameters included selectivity, linearity and limits of detection and quantification, intra- and interday precision and trueness, recovery and stability. The method included mixed-mode solid phase extraction, followed by microwave fast derivatization and analysis by gas chromatography-mass spectrometry operated in selected ion monitoring mode. The procedure was linear between 5 and 600 ng/mL, with determination coefficients higher than 0.99 for all analytes. Intra- and interday precision ranged from 0.1 to 13.6%, while accuracy variability was within 80-120% interval from the nominal concentration at all studied levels. The extraction efficiencies ranged from 76.6 to 112.8%. Stability was considered acceptable for all compounds in the studied matrices. The developed assay was applied to authentic samples of the Laboratory of Chemistry and Forensic Toxicology, Centre Branch, of the National Institute of Legal Medicine and Forensic Sciences, Portugal.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined