Prompt gamma-ray analysis of chlorine in superpozz cement concrete

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2012)

Cited 14|Views2
No score
Abstract
The chlorine concentration in Superpozz (SPZ) cement concrete was analyzed using a newly designed prompt gamma-ray neutron activation (PGNAA) setup utilizing a portable neutron generator. The setup, which mainly consists of a neutron source along with its moderator placed side by side with a shielded gamma-ray detector, allows determining chloride concentration in a concrete structure from one side. The setup has been tested through chlorine detection in chloride-contaminated Superpozz (SPZ) cement concrete specimens using 6.11 and 2.86±3.10MeV chlorine prompt gamma-rays. The optimum 0.032±0.012wt% value of Minimum Detectable Concentration (MDC) of chlorine in SPZ cement concrete measured in this study shows a successful application of a portable neutron generator in chloride analysis of concrete structure for corrosion studies.
More
Translated text
Key words
Concrete Corrosion Studies,Prompt Gamma Ray Analysis,Portable Neutron Generator,Chloride Analysis in Superpozz concrete,PGNAA portable design for field measurements