Test beam results with a sampling calorimeter of cerium fluoride scintillating crystals and tungsten absorber plates for calorimetry at the HL-LHC

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT(2016)

引用 1|浏览22
暂无评分
摘要
A sampling calorimeter using cerium fluoride scintillating crystals as active material, interleaved with absorber plates made of tungsten, and read out by wavelength-shifting fibres has been tested with high-energy electron beams at the CERN SPS H4 beam line, as well as with lower-energy beams at the INFN Frascati Beam Test Facility in Italy. Energy resolution studies revealed a low stochastic term ( < 100%/root E). This result, combined with high radiation hardness of the material used, marks this sampling calorimeter as a good candidate for the detectors' forward regions during the high luminosity phase of LHC. (C) 2015 Elsevier B.V. All rights reserved.
更多
查看译文
关键词
Beam test,Calorimeter,Cerium fluoride,HL-LHC,Sampling,Tungsten