Bioaerosol exposure to personnel in a clinical environment absent patients

JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE(2016)

引用 11|浏览4
暂无评分
摘要
Nosocomial infections pose a significant and escalating threat to both patients and healthcare workers (HCWs). By their nature, hospitals induce antibiotic resistance in virulent and commensal strains, leading to increasingly severe hospital-acquired infections. This study measured environmental exposure experienced by domestic staff cleaning vacated patient rooms of a community hospital to bacteria in ambient bioaerosols. While they cleaned the room, participants wore an N95 filtering facepiece respirator (FFR), from which coupons were cut and bacteria were extracted, cultured and enumerated. Extrapolation to the full area of the respirator yielded measured exposures of 0.2-1.4 x 10(4) colony-forming units/ hour, of which similar to 97% collected on the front layer of the N95, suggesting a possible role for minimal respiratory protection in nonpatient environments. Random resistance testing of 1.6% of the isolates showed that similar to 70% of both Gram-positive and Gram-negative organisms exhibited resistance to oxacillin and similar to 9% of the Gram-positives displayed resistance to vancomycin. These data provide an estimate formask bioaerosol loading that can be used in risk modeling and to refine strategies for reuse of FFRs during critical shortages.
更多
查看译文
关键词
Antibiotic resistance,background,hospital,infection,nosocomial,N95 respirator