Failure analysis of the condenser brass tube in 150 MW thermal power units

Engineering Failure Analysis(2013)

引用 10|浏览4
暂无评分
摘要
•The failure cause of a condenser brass tube was investigated.•The features of erosion were observed by macro and micro observations.•The necessary conditions for erosion were satisfied.•The dezincification–corrosion was also verified in this case study.•The failure is caused by the synergism of erosion and dezincification–corrosion.
更多
查看译文
关键词
Condenser brass tube,Erosion,Dezincification–corrosion,Failure analysis