Failure analysis of the condenser brass tube in 150 MW thermal power units
Engineering Failure Analysis(2013)
摘要
•The failure cause of a condenser brass tube was investigated.•The features of erosion were observed by macro and micro observations.•The necessary conditions for erosion were satisfied.•The dezincification–corrosion was also verified in this case study.•The failure is caused by the synergism of erosion and dezincification–corrosion.
更多查看译文
关键词
Condenser brass tube,Erosion,Dezincification–corrosion,Failure analysis
AI 理解论文
溯源树
样例
![](https://originalfileserver.aminer.cn/sys/aminer/pubs/mrt_preview.jpeg)
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要