Progression of myocardial fibrosis by magnetic resonance imaging in patients with Duchenne and Becker muscular dystrophy

Marly C Silva, Zilda M Meira, Juliana G Giannetti, Marco A Lara,Mariz Vainzof,Mayana Zatz,Roberto Kalil-Filho,Carlos E Rochitte

Journal of Cardiovascular Magnetic Resonance(2013)

引用 0|浏览7
暂无评分
摘要
Background Duchenne (DMD) and Becker (BMD) muscular dystrophy (MD) are inherited X-linked disease characterized by progressive skeletal muscle degeneration and myocardial involvement and caused by a mutation on dystrophin gene (Xp21). Dystrophin is a sarcolemal protein that links the cytoskeleton to the basal lamina and is essential for maintenance of the muscular membrane integrity during muscular contraction. In a previous study, our group described for the first time, in a small group of 10 patients, that CMR can identify myocardial fibrosis (MF) and may be useful for detecting the early stages of cardiomyopathy in MD [1]. The evolution of the myocardial fibrosis over time in this group of patient is still unknown. Methods We enrolled 76 pts, 70 pts with DMD and 6 BMD. Mean age was 13.1 ± 4.4 years. 74 patients underwent 2 CMR exams within a mean of 2.3 years, performed on a 1.5-T Siemens Avanto (Erlangen, Germany). Breath-hold LV short-axis and long-axis images were obtained by 2-pulse sequences at the same locations, allowing precise comparisons between LV function (gradient-echo sequence, steady-state free precession) and myocardial structure (inversion-recovery prepared gradient-echo sequence, 10 min after intravenous bolus or 0.2 mmol/kg gadolinium-based contrast), acquired with the following parameters, respectively: TR 2.0/ 9.0, TE 1.07/ 5.0; flip angle 69/50; cardiac phases 20/1; VPS 8/16 to 32; matrix 192 x 162 / 256 x 192; ST 8/8 mm; gap 2/2 and FOV 32 to 38/32 to 38 cm; TI none/150 to 390 ms; receiver bandwidth 930/150 Hz; number of excitations 1/1; acquisition every other heartbeat for MDE. The images were analyzed by two experienced observers. End-systolic LV volume, end-diastolic LV volume and LV ejection fraction were measured by the Simpson method using Argus software, Siemens. For the MDE short axis images, we evaluated the MF mass per patient, using a 5 standard deviation thresholding technique, on a CMR42 software, version 3.4.2 (Circle Cardiovascular Imaging, Calgary, Alberta, Canada). Normal LVEF was defined as above 50%. Test of Wilcoxon was used for comparison of myocardial fibrosis between baseline and follow-up CMR studies. Results Two patients died before the follow-up CMR. For all 74 patients, MF increased significantly from 11.3 ± 12.2 g on the baseline CMR to 15.9 ± 15.4 g, p<0.001. The number of segments with MF increased from 3.7 ± 3.3 to 5.1 ± 3.6, p<0.001. In a sub-group with LV dysfunction (n=11) MF increased from 26.9 ± 13.0 g to 35.5 ± 20.2 g, p=0.021. In a sub-group of patients with normal LVEF and no fibrosis (n=21) on the baseline CMR, MF progressed from 0 g to 1.5 ± 3.7 g, p=0.08. Conclusions Myocardial fibrosis detected by CMR progressively increases in patients with Duchenne and Becker muscular dystrophy over a period of 2.3 years. The progression occurs not only in patients with more advanced cardiomyopathy and LV dysfunction, but also in patients with normal function and no myocardial fibrosis at the baseline CMR.
更多
查看译文
关键词
Muscular Dystrophy, Myocardial Fibrosis, Becker Muscular Dystrophy, Normal LVEF, Circle Cardiovascular Image
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要