Chrome Extension
WeChat Mini Program
Use on ChatGLM

Full-scale burning tests on double-skin façade fires: FULL-SCALE BURNING TESTS ON DOUBLE-SKIN FAÇADE FIRES

Fire and Materials(2013)

Cited 22|Views2
No score
Abstract
Fire hazard of an architectural feature with double-skin facade is a concern. An identified scenario of having a post-flashover room fire adjacent to the facade was studied experimentally in a rig of 6?m tall. Eight tests of cavity depths including a wide value of 2?m, normal values of 1.5?m and 1?m and a narrow value of 0.5?m under a room flashover fire of 1200?kW were carried out. From the measured air temperature profiles inside the facade cavity, the chance of breaking the interior glass pane above the fire room is therefore very high. Copyright (c) 2012 John Wiley & Sons, Ltd.
More
Translated text
Key words
double-skin facade,fire hazard,experimental study