The Evaluation Of The Design And Operation Of The 400mw Evaporative Cooling Hydrogenerator In Lijiaxia Hydropower Station

Ruan Lin,Liu Feihui,Gu Guobiao, Wang Xingang, Sun Tianhu

2015 18TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS)(2015)

Cited 23|Views8
No score
Abstract
The 400MW evaporative cooling hydrogenerator in Lijiaxia hydropower station has been serving for more than 15 years. This paper gives a comprehensive evaluation of this unit from cooling mode selection, electrical magnetic scheme design, operating practice and temperature distribution. The application of the evaporative cooling technology to 400MW-grade hydrogenerator shows great advantages comparing with the same capacity air cooling units, which demonstrates the correct of design and the stability and safety of long-term operation.
More
Translated text
Key words
decision support systems,thermal stability,maintenance engineering
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined