Status report on the CMS forward muon upgrade with large-size triple-GEM detectors

D. Abbaneo,M. Abbas, M. Abbrescia,A.A. Abdelalim,M. Abi Akl,W. Ahmed, W. Ahmed, P. Altieri,R. Aly, C. Asawatangtrakuldee, A. Ashfaq,P. Aspell,Y. Assran,I. Awan, S. Bally,Y. Ban, S. Banerjee,P. Barria,L. Benussi, V. Bhopatkar,S. Bianco,J. Bos, O. Bouhali,S. Braibant,S. Buontempo, C. Calabria,M. Caponero,C. Caputo, F. Cassese,A. Castaneda,S. Cauwenbergh, F.R. Cavallo,A. Celik, M. Choi, K. Choi,S. Choi,J. Christiansen,A. Cimmino,S. Colafranceschi,A. Colaleo,A. Conde Garcia,M.M. Dabrowski,G. De Lentdecker,R. De Oliveira,G. de Robertis,S. Dildick, B. Dorney,W. Elmetenawee,G. Fabrice, M. Ferrini,S. Ferry,P. Giacomelli,J. Gilmore, L. Guiducci,A. Gutierrez, R.M. Hadjiiska,A. Hassan,J. Hauser, K. Hoepfner,M. Hohlmann,H. Hoorani, Y.G. Jeng,T. Kamon,P.E. Karchin, H.S. Kim,S. Krutelyov,A. Kumar,J. Lee,T. Lenzi,L. Litov,F. Loddo, T. Maerschalk, G. Magazzu, M. Maggi,Y. Maghrbi,A. Magnani,N. Majumdar,P.K. Mal,K. Mandal,A. Marchioro, A. Marinov,J.A. Merlin,A.K. Mohanty, A. Mohapatra,S. Muhammad,S. Mukhopadhyay,M. Naimuddin, S. Nuzzo,E. Oliveri,L.M. Pant,P. Paolucci,I. Park, G. Passeggio,B. Pavlov, B. Philipps, M. Phipps, D. Piccolo, H. Postema,G. Pugliese,A. Puig Baranac,A. Radi, R. Radogna, G. Raffone,S. Ramkrishna, A. Ranieri,C. Riccardi,A. Rodrigues,L. Ropelewski,S. RoyChowdhury,M.S. Ryu,G. Ryu, A. Safonov,A. Sakharov,S. Salva, G. Saviano,A. Sharma,S.K. Swain, J.P. Talvitie,C. Tamma, A. Tatarinov, N. Turini, T. Tuuva, J. Twigger,M. Tytgat,I. Vai,M. van Stenis, R. Venditi,E. Verhagen,P. Verwilligen, P. Vitulo,D. Wang,M. Wang,U. Yang,Y. Yang,R. Yonamine, N. Zaganidis,F. Zenoni,A. Zhang

2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)(2014)

引用 0|浏览4
暂无评分
摘要
For the High-Luminosity LHC (HL-LHC) phase the CMS GEM Collaboration is planning to install new large-size (990×220–455mm2) triple-GEM detectors, equipped with a new readout system, in the forward region of the muon system (1.5< |η| <2.2) of the CMS detector. Combining triggering and tracking functionalities the new triple-foil Gas Electron Multiplier (GEM) chambers will improve both the performance of the CMS muon trigger and the muon reconstruction/identification in CMS experiment. The addition of triple-GEM chambers to the forward region of the CMS muon system will add a necessary layer of redundancy. Starting from 2009 the CMS GEM Collaboration has built several small and full-size prototypes with different geometries, keeping improving the assembly techniques. All these prototypes have been tested in laboratories as well as with beam tests at the CERN Super Proton Synchrotron (SPS) and at Fermi National Accelerator Laboratory. In this contribution we will report on the status of the CMS upgrade project with triple-GEM chambers and its impact on the CMS performance as well as the hardware architectures and expected capability of the CMS GEM readout system.
更多
查看译文
关键词
general
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要