Development Of Liquid Helium-Free Superconducting Magnet

IEICE TRANSACTIONS ON ELECTRONICS(1995)

Cited 22|Views5
No score
Abstract
Cryocooler cooled superconducting magnets using Bismuth based high-T-c current leads have been successfully demonstrated. The magnets mainly consisted of a superconducting coil, current leads and a radiation shield which are cooled by a two stage Gifford-McMahon cryocooler without using liquid helium. Our first liquid helium-free 4.6 T (Nb, Ti)(3)Sn superconducting magnet with a room temperature bore of 38 mm operated at 11 K has recorded a continuous operation at 3.7 T for 1,200 hours and total cooling time over 10,000 hours without trouble. As a next step, we constructed a (Nb, Ti)(3)Sn liquid helium-free superconducting magnet with a wider room temperature bore of 60 mm. The coil temperature reached 8.3 K in 37 hours after starting the cryocooler. The magnet generated 5.0 T at the center of the 60 mm room temperature bore at an operating current of 140 A. An operation at a field of 5 T was confirmed to be stable even if the cryocooler has been stopped for 4 minutes. These results show that the liquid helium-free superconducting magnets can provide an excellent performance for a new application of the superconducting magnet.
More
Translated text
Key words
LIQUID HELIUM-FREE, SUPERCONDUCTING MAGNET, BISMUTH BASED SUPERCONDUCTING CURRENT LEAD, GM CRYOCOOLER