Chrome Extension
WeChat Mini Program
Use on ChatGLM

CMR measurements of myocardial infarct heterogeneity using MCLE and IR-FGRE: correlation with arrhythmia inducibility and severe ICD events in patients with ischemic heart disease

Journal of Cardiovascular Magnetic Resonance(2012)

Cited 0|Views7
No score
Abstract
Summary This study used CMR to evaluate patients with IHD prior to ICD implantation and correlated CMR measurements to VA inducibility and spontaneous VA events during follow-up. The results demonstrated that the gray-zone measurement using MCLE may be more sensitive in predicting appropriate ICD therapy for VA. Background In addition to measures of left ventricular ejection fraction (LVEF) and clinical staging of heart failure, myocardial infarct (MI) heterogeneity including MI and periinfarct gray-zone (GZ) has the potential to predict the occurrence of inducible sustained ventricular arrhythmia (VA) and spontaneous VA events after implantation of implantable defibrillator (ICD) in patients with ischemic heart disease (IHD). Late-gadolinium (Gd)-enhancement (LGE) cardiac MR (CMR) using inversion-recovery fastgradient-echo (IR-FGRE) is commonly used for the determination of infarct heterogeneity in these patients. Recently, a multi-contrast late-enhancement (MCLE) sequence has been developed for better infarct heterogeneity quantification. Compared to IR-FGRE, we hypothesized that MCLE may be a more sensitive method to predict the occurrence of inducible VA and severe events post-ICD implantation. Methods This study used CMR to evaluate patients with IHD prior to ICD implantation and correlated CMR measurements to VA inducibility and spontaneous VA events during follow-up. The MRI protocol included LV functional parameter assessment using steady-state free precession (SSFP), as well as LGE-MRI using IR-FGRE and MCLE post double-dose Gd injection. LV functional parameters were measured using Q-Mass or CMR42 software. The GZ analysis in IR-FGRE used a full-width half-maximum method. For MCLE, GZ analysis used a semi-automated data clustering algorithm. An unpaired t-test with unequal variance was used for the statistical analysis of the proportion of GZ, MI core and total MI relative to LV myocardium mass. Results
More
Translated text
Key words
Left Ventricular Ejection Fraction, Ischemic Heart Disease, Ventricular Arrhythmia, Average Left Ventricular Ejection Fraction, Sustained Ventricular Arrhythmia
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined