DARHT-II Long-Pulse Electron Beam

2007 IEEE 34th International Conference on Plasma Science (ICOPS)(2007)

引用 0|浏览37
暂无评分
摘要
Summary form only given. The second axis of the dual-axis radiographic hydrotest (DARHT) facility will provide four radiographic images within ~1.6 microseconds. This will be accomplished by slicing four short pulses out of a ~1.6-microsecond long electron beam produced by the DARHT-II linear induction accelerator and directing them onto a bremsstrahlung converter target. Commissioning of the full 17-MeV configuration the DARHT-II accelerator will begin in spring of 2007 following tests of a new high-perveance (2 kA at 2.5 MV) diode. We will present the results of diode performance measurements as well as initial measurements of the fully accelerated electron beam parameters.
更多
查看译文
关键词
linear accelerators,acceleration,diodes,measurement,radiography,electron beam,testing