Development of Chinese hybrid radiation adult phantoms and their application to external dosimetry

Science China-technological Sciences(2014)

Cited 22|Views2
No score
Abstract
This paper presents the construction of Chinese hybrid radiation adult phantoms, which are compatible with anatomical parameters for the Chinese reference population. The phantoms were designed using polygonal mesh surface, which makes the phantom more flexible and realistic than previous generations. Voxelization of hybrid phantoms was performed to adopt Monte Carlo methods. External dose coefficients were calculated by Geant4 and compared to the ICRP reference phantom. The results show that the organ dose is different from ICRP116 with the low energy photons, which can be ascribed to the anatomy and topology difference of each organ. The effective dose of CHRAP is 19% higher than ICRP 116 in the energy range from 10 to 100 keV and is almost the same in the energy range from 100 keV to 10 MeV. These phantoms can be used as the basic phantom to adjust the posture or organ volume to estimate dosimetry in medical and space explorations.
More
Translated text
Key words
CHRAP,radiation computational phantoms,dosimetry,Monte Carlo calculations