Increased heart rate caused by atrial pacing with the closed-loop stimulation function prevented micturition syncope

Journal of Arrhythmia(2013)

Cited 0|Views6
No score
Abstract
A 70-year-old man had been experiencing syncope several times a year. We implanted a DDD pacemaker with closed-loop stimulation (CLS) function. When he urinated early in the morning, his increased atrial pacing rates elevated his heart rate (HR) during and after micturition. After implantation of the DDD-CLS mode, he did not experience symptoms. In contrast, in the DDD-R mode, his intrinsic HR changed to atrial pacing after micturition but decreased to the basal rate within 2min, and he experienced a sense of cold perspiration and presyncope. Increased HRs caused by atrial pacing with the CLS function were useful in the prevention of micturition syncope.
More
Translated text
Key words
Micturition syncope,Closed-loop stimulation,Pacemaker,Atrial pacing