The Data Acquisition System For The Koto Detector

M Tecchio,Jon Ameel,Mircea Bogdan,M Campbell,J R Comfort, Craig Harabedian, E Iwai, Shumin Li,Jiasen Ma,Duncan Mcfarland, Angela Steinmann, Yasuyuki Sujiyama,Y Wah

PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011)(2012)

引用 7|浏览32
暂无评分
摘要
The Data Acquisition (DAQ) for the KOTO detector is designed around a 14-bit 125MHz ADC module, which measures the energy and the time of photomultiplier pulses from about 4000 readout channels. The Trigger has a two-tiered design, with a first level decision based on the time-aligned energy sum over the entire calorimeter and a second level decision based on clustering and in-time veto signal rejection. Data accepted by the second level trigger are read out via Gigabit Ethernet and passed to a computer farm for event building and data storage. (C) 2012 Published by Elsevier B.V. Selection and/or peer review under responsibility of the organizing committee for TIPP 11.
更多
查看译文
关键词
DAQ, trigger, KOTO