MicroTCA-based Global Trigger Upgrade project for the CMS experiment at LHC

Babak Rahbaran, Benjamin Arnold,H Bergauer, M Eichberger,Dinyar Rabady

JOURNAL OF INSTRUMENTATION(2011)

引用 2|浏览21
暂无评分
摘要
The electronics of the first Level Global Trigger (GT) of CMS is the last stage of the Level-1 trigger system [1]. At LHC up to 40 million collisions of proton bunches occur every second, resulting in about 800 million proton collisions. The CMS Level-1 Global Trigger [1], a custom designed electronics system based on FPGA technology and the VMEbus system, performs a quick on-line analysis of each collision every 25 ns and decides whether to reject or to accept it for further analysis. The CMS trigger group of the Institute of High Energy Physics in Vienna (HEPHY) is involved in the Level-1 trigger of the CMS experiment at CERN. As part of the Trigger Upgrade, the Level-1 Global Trigger will be redesigned and implemented in MicroTCA based technology, which allows engineers to detect all possible faults on plug-in boards, in the power supply and in the cooling system. The upgraded Global Trigger will be designed to have the same basic categories of functions as the present GT, but will have more algorithms and more possibilities for combining trigger candidates. Additionally, reconfigurability and testability will be supported based on the next system generation.
更多
查看译文
关键词
Trigger concepts and systems (hardware and software),Front-end electronics for detector readout,Detector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms, databases)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要