Extrinsic compression of the left main coronary artery by a contained aortic annular rupture following trans-catheter aortic valve implantation

Cardiovascular Revascularization Medicine(2015)

Cited 3|Views21
No score
Abstract
We present a case of an 83-year-old female who suffered from annular rupture with contained hematoma immediately after trans-apical implantation of balloon-expandable Sapien valve. The patient developed acute cardiogenic shock which resulted from an extrinsic compression of the left main coronary artery. We report the successful management of this complication.