Quantitative determination of tenuazonic acid in pig and broiler chicken plasma by LC-MS/MS and its comparative toxicokinetics

JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY(2015)

Cited 22|Views9
No score
Abstract
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantitate tenuazonic acid (TeA) in pig and broiler chicken plasma was successfully developed and validated. Linear matrix-matched calibration curves ranged between 5 and 200 ng/mL. Correlation coefficients, goodness-of-fit coefficients, and within-day and between-day precision and accuracy fell well within the acceptance criteria. The limit of quantitation was 5.0 ng/mL in both pig and broiler chicken plasma. The LC-MS/MS method was applied in a comparative toxicokinetic study in both pigs and broiler chickens. TeA was completely bioavailable after oral administration in both animal species. However, absorption was deemed to be slower in broiler chickens (mean t(max) 0.32 h in pigs vs 2.60 h in chickens). TeA was more slowly eliminated in broiler chickens (mean t(1/2el) 0.55 h in pigs vs 2.45 h in chickens after oral administration), mainly due to the significantly lower total body clearance (mean Cl 446.1 mL/h/kg in pigs vs 59.2 mL/h/kg in chickens after oral administration). Tissue residue studies and further research to elucidate the biotransformation and excretion processes of TeA in pigs, broiler chickens, and other animal species are imperative.
More
Translated text
Key words
tenuazonic acid,LC-MS/MS,toxicokinetics,oral bioavailability,broiler chicken,pig
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined