Chrome Extension
WeChat Mini Program
Use on ChatGLM

Recoarctation after fracture of stent implanted for native aortic coarctation: case report.

Revista portuguesa de cardiologia : orgão oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology(2009)

Cited 25|Views3
No score
Abstract
We report the case of a 20-year-old patient with severe arterial hypertension in whom coarctation of the aorta was diagnosed. She underwent cardiac catheterization with balloon dilation and stent implantation, with a good initial result. After this procedure she improved and her blood pressure was under control for six months. Her condition then worsened and she developed signs of recoarctation, with an increased Doppler pressure gradient in the descending aorta. On recatheterization a stent fracture was detected and treated with percutaneous implantation of a covered stent inside the previous one, with sustained improvement. Stent fracture is a rare complication of stent implantation in the aorta. Several etiological hypotheses and treatment options are reviewed.
More
Translated text
Key words
native aortic recoarctation,stent,fracture