Hemodynamic analysis of coronary circulation in angulated coronary stenosis following stenting.

YONSEI MEDICAL JOURNAL(2002)

Cited 8|Views7
No score
Abstract
The present study in angulated coronary stenosis used human in vivo hemodynamic parameters and computed simulation, both qualitatively and qualitatively, to evaluate the influence of flow velocity and wall shear stress (WSS) on coronary atherosclerosis, the changes of hemodynamic indices following coronary stenting, and their effect on evolving in-stent restenosis. Initial and follow-up coronary angiographies in patients with angulated coronary stenosis were performed (n=60). The optimal degree of coronary stenting for angulated coronary stenosis had two models, the less than 50% angle changed group (model 1, n=33) and the more than 50% angle changed group (model 2, n=27). This angle change was based on the percentage change of vascular angle between pre- and post-intracoronary stenting. The flow-velocity wave obtained from in vivo intracoronary Doppler study data was used for in vitro numerical simulation. Spatial and temporal patterns of the flow-velocity vector and recirculation area were drawn throughout the selected segment of coronary models. WSS of pre- and post-intracoronary stenting was calculated from three-dimensional computer simulation. As results, follow-up coronary angiogram demonstrated significant difference in the percentage of diameter stenosis between the two groups (group 1: 40.3 +/- 30.2 vs. group 2: 25.5 +/- 22.5%, p<0.05). Negative shear area on 3D simulation, which is consistent with the re-circulation area of flow vector, was noted on the inner wall of the post-stenotic area before stenting. The negative WSS disappeared after stenting. High spatial and temporal WSS before stenting fell within the range of physiologic WSS after stenting. This finding was more prominent in model 2 (p<0.01). The present study suggests that hemodynamic forces exerted by pulsatile coronary circulation, termed WSS, might affect the evolution of atherosclerosis within the angulated vascular curvature. Moreover, geometric characteristics, such as the angular difference between pre- and post- intracoronary stenting might define optimal rheologic properties for vascular repair after stenting.
More
Translated text
Key words
wall shear stress,in-stent restenosis,hemodynamic analysis,angulated coronary stenosis
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined