Comparison of the dosimetries of 3-dimensions Radiotherapy (3D-RT) with linear accelerator and intensity modulated radiotherapy (IMRT) with helical tomotherapy in children irradiated for neuroblastoma

BMC medical physics(2012)

Cited 12|Views3
No score
Abstract
Background Intensity modulated radiotherapy is an efficient radiotherapy technique to increase dose in target volumes and decrease irradiation dose in organs at risk. This last objective is mainly relevant in children. However, previous results suggested that IMRT could increase low dose, factor of risk for secondary radiation induced cancer. This study was performed to compare dose distributions with 3D-radiotherapy (3D-RT) and IMRT with tomotherapy (HT) in children with neuroblastoma. Seven children with neuroblastoma were irradiated. Treatment plans were calculated for 3D-RT, and for HT. For the volume of interest, the PTV-V 95% and conformity index were calculated. Dose constraints of all the organs at risk and integral dose were compared. Results The conformity index was statistically better for HT than for 3D-RT. PTV-V 95% constraint was reached in 6 cases with HT compared to 2 cases with 3D-RT. For the ipsilateral kidney of the tumor, the V 12 Gy constraint was reached for 3 patients with both methods. The values were lower with HT than with 3D-RT in two cases and higher in one case. The threshold was not reached for one patient with either technique, but the value was lower with HT than with 3D-RT. For the contralateral kidney of the tumors, the V 12 Gy constraint was reached for all patients with both methods. The values were lower with HT than with 3D-RT in 5 of 7 children, equal in one patient and higher in one patient. The organ-at-risk volumes receiving low doses were significantly lower with 3D-RT but larger for the highest doses, compared to those irradiated with HT. The integral doses were not different. Conclusions IMRT with HT allows a better conformity treatment, a more frequently acceptable PTV-V 95% than 3D-RT and, concomitantly, a better shielding of the kidneys. The integral doses are comparable between both techniques but consideration of differences in dose distribution between the two techniques, for the organs at risk, has to be taken in account when validating treatment.
More
Translated text
Key words
Neuroblastoma,IMRT,3D-RT,Tomotherapy,Dosimetry
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined