Template For Preparation Of Papers For Ieee Sponsored Conferences & Symposia

2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)(2011)

引用 0|浏览4
暂无评分
摘要
Rotary blood pumps which have contact-less suspension are small, durable and widely used for left ventricular assist devices (LVADs). In order to design a total artificial heart (TAH) with rotary blood pumps, two pumps one for each ventricle, are controlled independently. Some of the challenges for the development of a TAH includes the requirement of a small size and the anatomical fitting of inlets and outlets which should be arranged closely on the circumference in the same direction. And they should be combined into a unit. In this paper, a helical flow total artificial heart (HFTAH) combing two centrifugal pumps with helical inlet in face is proposed in order to achieve a smaller TAH. To examine the pump performance, a preliminary test model for left ventricle was built, the size of the pump was 69.0mm in diameter and 45.0mm height. The size of the impeller was 44.0mm in diameter and 23.0mm height including a 15.0mm-height hydrodynamic bearing. The pump was externally driven by a direct current motor. 5.0L/min flow rate against 100mmHg pressure difference was obtained, where the total power consumption was 5.0W, the system efficiency was 23% with a rotational speed of 2070rpm. In this system, maximum pressure head, flow rate and efficiency were 420mmHg, 15.0L/min and 26%, respectively. In acute animal experiments with three healthy adult goats, the total biventricular bypass assist system using the pumps was able to maintain the maximum aortic flow at approximately 5.0L/min, and the pulmonary arterial flow at approximately 4.6L/min, the mean aorta pressure was 105mmHg, and the mean pulmonary artery pressure was 51mmHg. The development of the control method is undergoing, and a driving system and the pump aiming at the chronic animal experiments will be developed.
更多
查看译文
关键词
biomedical equipment,blood flow measurement,blood pressure measurement,blood vessels,cardiovascular system,lung,medical control systems,pumps,IEEE sponsored conferences & symposia,anatomical fitting,aortic flow,biventricular bypass assist system,centrifugal pumps,chronic animal experiments,contact-less suspension,control method,direct current motor,driving system,flow rate,helical flow,helical inlet,hydrodynamic bearing,impeller,left ventricular assist devices,outlets,power 5.0 W,preliminary test model,pulmonary arterial flow,pulmonary artery pressure,rotary blood pumps,size 23.0 mm,size 44.0 mm,size 45.0 mm,size 69.0 mm,total artificial heart,
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要