Polyethylene wear after total hip arthroplasty: the effect of a modular femoral head with an extended flange-reinforced neck.

JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME(1998)

Cited 39|Views1
No score
Abstract
The use of modular components in total hip arthroplasty has been thought to contribute to accelerated polyethylene wear. Specifically, a modular femoral head with a flange extension and a longer neck may cause increased wear. The purpose of the current study was to evaluate the effect of a flange extension on polyethylene wear. Ninety-one patients who had had a total of 100 primary total hip arthroplasties were evaluated after an intermediate duration of follow-up. All of the acetabular components consisted of a hemispherical titanium-alloy fiber-mesh porous-coated shell with a nonelevated modular polyethylene liner; they were inserted without cement and with use of supplemental screws through the dome after so-called line-to-line reaming, All of the femoral components consisted of a modular head with a diameter of twenty-eight millimeters and either a long neck (with a flange extension) or a short or medium neck (without a flange extension). The study group comprised sixty-two patients (sixty-six hips) who had had radiographic evaluation that was adequate to allow the valid measurement of polyethylene wear, Thirty-two hips were in men, and thirty-four were in women. The mean age of the patients was fifty-six years, the mean weight was seventy-three kilograms, and the mean duration of follow-up was 6.1 years (range, four to eight years). The rate of polyethylene wear in the eleven hips in which the femoral component had a flange extension was significantly greater than that in the fifty-five in which the femoral component did not have a flange extension (mean, 0.17 compared with 0.11 millimeter per year; p = 0.009), Multivariate analysis showed that the presence of a flange extension was associated with increased polyethylene wear to a greater degree (F = 2.86) than were all other variables that were measured, including a younger age (F = 1.72), a more vertical angle of the acetabular component (F = 0.49), a heavier weight (F = 0.14), male gender (F = 0.11), and a smaller initial thickness of the polyethylene (F = 0.02). These data support an association between the presence of a modular femoral head with a flange extension and an accelerated rate of polyethylene wear, The presumed mechanism is an increase in peripheral, or so-called rim, impingement of the flange-reinforced neck on the acetabulum due to a decrease in the ratio between the diameters of the femoral head and neck.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined