Spectroscopic Measurement Of Ion Temperature And Ion Velocity Distributions In The Flux-Coil Generated Frc

REVIEW OF SCIENTIFIC INSTRUMENTS(2010)

引用 7|浏览5
暂无评分
摘要
One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field. (C) 2010 American Institute of Physics. [doi:10.1063/1.3485090]
更多
查看译文
关键词
reversed field pinch,transimpedance amplifier,field reversed configuration,electric field,spectrum,high frequency