Paradoxical effects of aurintricarboxylic acid and RG-13577: acute thrombosis and in-stent stenosis in a passive-coated stent.

JOURNAL OF ENDOVASCULAR THERAPY(2006)

Cited 2|Views31
No score
Abstract
Purpose: To investigate if a platelet inhibitor (aurintricarboxylic acid [ATA]) and a heparin-mimicking antagonist (RG-13577) of basic fibroblast growth factor 2 (bFGF2) could be combined as a stable compound and attached to conventional bare metal stents to hinder thrombus formation and inflammatory reactions of stenting. Methods: Fifteen domestic pigs were stented with RG-13577/ATA-coated (n=6), ATA-coated (n=12), and bare metal stents (n=12) in the left anterior descending (LAD) and left circumflex (LCX) coronary arteries. All surviving pigs were evaluated with contrast angiography and intravascular ultrasonography (IVUS) after 4 weeks. Histological analysis of the stented arteries was performed after hematoxylin-eosin staining. Tissue factor (TF) staining and scanning electron microscopy (SEM) were performed in animals with acute stent thrombosis. Results: Five of the 6 animals receiving an RG-13577/ATA-coated stent experienced acute stent thrombosis, while no adverse events occurred in the animals of the other 2 groups. Follow-up angiography did not show significant in-stent stenosis in either bare or ATA-coated stents. However, histomorphometry revealed larger neointimal area (3.54 +/- 0.69 mm(2) versus 1.82 +/- 0.27 mm(2), p < 0.05) and outward plaque area (1.56 +/- 0.34 mm(2) versus 0.61 +/- 0.12 mm(2), p < 0.05) in ATA-coated stents. Three-dimensional IVUS analysis showed analogous results, with significantly larger neointimal volume and outward plaque volume in ATA-coated stents. There was a slight increase in TF staining around the stent struts, while SEM showed increased platelet adhesion and activity in RG-13577/ATA-coated stents versus the ATA-coated and bare metal stents. Conclusion: RG-13577/ATA-coated stents lead to acute stent thrombosis. The ATA coating alone did not lead to acute events, but resulted in higher neointimal hyperplasia and expansive remodeling. These results underline the importance of preclinical studies before using new coated stents in human arteries.
More
Translated text
Key words
in-stent restenosis,porcine model,coronary arteries,RG-13577,aurintricarboxylic acid,stent,platelet inhibitor
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined