Common-Mode Choke Coils Characterization

Barcelona(2009)

Cited 1|Views2
No score
Abstract
Common-mode (CM) chokes are four-terminal devices with different CM and differential-mode (DM) characteristics. The paper reviews the models for two- and four-terminal inductors and presents two methods to obtain the CM and DM characteristics of four-terminal devices. More specifically, it shows how the insertion loss and pi-equivalent circuits of a CM choke can be obtained using two- and four-port network parameters. However, these characterization methods are applicable not only to CM chokes, but to any four-terminal component or network, such as single-phase power filters.The results show that second order linear circuit models cannot describe accurately the CM and DM characteristics of a CM choke over a wide frequency range. For the studied example, the DM characteristics were more complex than the CM ones.
More
Translated text
Key words
EMC/EMI,measurement,passive component,passive filter
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper