Results of the Installation of a Prepulse Reduction System on the PIM Blumlein

Monterey, CA(2005)

引用 3|浏览3
暂无评分
摘要
In the PIM pulsed power machine a 1.5 MV, 100 ns duration pulse is generated by a 10 Ohm water Blumlein A prepulse reduction system based on a gas switch has been designed and built by Titan PSD. This has been fitted and reduced the prepulse to less than 3 kV. Prepulse of this order is necessary to drive the focused e-beam diodes used for flash radiography. Details of the prepulse reduction system, the experimental data obtained and comparison with computer models of the machine will be presented.
更多
查看译文
关键词
adders,diodes,pulsed power supplies,radiography,electron-beam diodes,flash radiography,gas switch,inductive voltage adder,prepulse reduction system,prototype iva module,pulsed power machine,resistance 10 ohm,time 100 ns,voltage 1.5 mv,water blumlein,voltage,testing,conductors,impedance,computer model,plasmas,switches,prototypes