Anatomical considerations for the placement of cervical transarticular screws.

JOURNAL OF NEUROSURGERY-SPINE(2011)

引用 14|浏览4
暂无评分
摘要
this study establishes anatomical guidelines to allow for safe cervical transarticular screw insertion. The starting point of transarticular screws should be 1 mm medial to the midpoint of the lateral mass. The "ideal" drilling angle is approximately 37° in the inferior direction and 16° in the lateral direction for the C2-3 through the C5-6 levels. The screw should be directed as laterally as possible in the axial plane without causing the lateral mass to fracture and as caudally as the occipital bone permits in the sagittal plane. The ideal screw size would be 3.5 mm in diameter and 18 mm in length.
更多
查看译文
关键词
cervical spine,fixation,transarticular facet,bone screw