A mechanical and experimental study on the heat loss of solar evacuated tube

Journal of Shanghai Jiaotong University (Science)(2009)

引用 0|浏览18
暂无评分
摘要
The experimental system of heat loss of all-glass evacuated solar collector tubes (evacuated tube) is firstly designed and constructed, which uses electric heater as thermal resource. The equilibrium temperatures are less than ±1°C during the test, and the temperature differences of up/middle/low node in the tube are less than 1°C, 3°C, and 7°C respectively. The heat loss of evacuated tube increases about 2.7% with vacuum state of 0.01–1 mPa, and it has the best performance at tube temperature of 20–280°C. The invalidation tube (> 200 mPa) has the biggest heat loss that increases linearly with the tube temperature. The evacuated tubes with the vacuum of 0.01–1 mPa are suitable for most solar adsorption refrigeration.
更多
查看译文
关键词
all-glass evacuated solar collector tube,adsorption refrigeration,vacuum state,heat loss,equilibrium temperature